AM 3000 – Air Sampler for Asbestos Diagnosis – NF43-050 version 2021, NF X43-269, NF EN ISO 13137

  • AUTONOMOUS SAMPLING: The AM 3000 is an autonomous air sampler, ensuring consistent and reliable sampling without manual intervention.
  • HIGH PRECISION: Equipped with a pump whose flow rate is automatically regulated by a microcontroller and a mass flow meter.
  • REMOTE CONTROL: Can be remotely operated using an infrared remote control, enhancing user convenience.
  • ROBUST & WATERPROOF: The device is robust, stackable, and has an IP65 protection rating, ensuring its durability and resistance to environmental factors.
  • CERTIFIED COMPLIANCE: Meets the strict requirements of NF43-050, NF X43-269, and NF EN ISO 13137 standards, ensuring its reliability and adherence to industrial norms.

AM 3000 - Air Sampler for Asbestos Diagnosis

3560,00 

In stock

Fan for AM 3000

75,00 
Le ventilateur SDEC permet le maintien en suspension des particules et fibres d'amiante.

In stock

Pack Batterie Externe 21Ah 24V pour AM 3000

685,00 
Nous avons conçu ce Pack Batterie afin de proposer une source autonome permettant d'alimenter un ventilateur SDEC.

In stock

– Operating Principle –

The AM 3000 is an autonomous air sampler specifically designed to meet the constraints and requirements of fieldwork. Compact and highly robust, it benefits from numerous technological innovations that guarantee a representative sampling of asbestos fibers or other fine particles in the air. Meeting the requirements of NF X43-050, NF X43-269, and NF EN ISO 13137 standards, it ensures sampling for MOCP (2 L/min) and META (7 L/min) analyses.

The AM 3000 is robust, easy to handle, and stackable. Usable in both horizontal and vertical operations, it is suitable for office environments (very quiet) as well as indoor or outdoor construction zones. It is rain-resistant and can be decontaminated with a water jet thanks to its IP65 protection rating. To avoid internal contamination, the casing is sealed, and the intake is equipped with a self-sealing quick connector.

 

– Remote Control Operation –

The AM 3000 is fully programmable and can be remotely configured using an infrared remote control. A single remote control can operate all samplers. The AM 3000 is supplied with two remote controls (including one spare).

 

– Direct Data Accessibility –

Thanks to the USB output, the operator can retrieve data in a computer file format (.CVS compatible with Excel) on a USB stick. With its USB/micro-USB cable (available on request) and a text file reader or spreadsheet application like Excel, the file containing all the sampling details can be consulted on a smartphone directly on-site.

 

– Complete Autonomy with an Integrated Protected Battery –

With its integrated lithium battery, the AM 3000 operates completely autonomously. Its waterproof charger is decontaminable. The device can be used on mains power and recharge the battery simultaneously during sampling. In the event of a mains power cut, it will automatically switch to the battery without interrupting the sampling.

The battery is enclosed in a protective aluminum casing, protecting it from impact and puncture risks. It enhances thermal stability and minimizes the risk of thermal runaway.

A shock indicator is positioned on the battery and also on the outside of the device. In the event of a shock sensitivity of 100 G (equivalent to a fall from about one meter), the indicator turns red, showing poor treatment of the device and possible damage to internal components. The user is then advised to return the device for service.

– Secure Sampling –

Sampling is secured by continuous monitoring of the air flow. If there is a significant deviation from the set flow rate (due to aerodynamic circuit problems or tampering), the device goes into safety mode and stops the sampling to protect the pump. The fault is recorded and accessible on the display and the CSV file.

 

– Official Supplier –

Various nuclear power plants in Europe and worldwide.

 

– About SDEC –

SDEC is your global partner for SDEC solutions in radioprotection. Welcome to the world of SDEC France, a leader in environmental and scientific solutions for radioprotection in over 21 countries. Since 1991, SDEC France has been designing, manufacturing, and marketing a wide range of equipment for environmental study and monitoring.

 

 

– FAQ –

How does the AM 3000 ensure the safety of the sampling process?

Sampling is secured through continuous air flow monitoring. In case of a significant deviation from the set flow rate (due to an issue in the aerodynamic circuit or tampering), the device switches to safety mode, stopping the sampling to protect the pump. The fault is recorded and can be reviewed on the display and in the CSV file.

How does the AM 3000 alert users in case of potential damage or mishandling?

The device is equipped with a shock indicator located on both the battery and the exterior of the device. If the device undergoes a shock equivalent to a fall of about one meter, the indicator turns red, signaling potential internal component damage and the need for service.

What ensures the autonomy and safety of the AM 3000’s battery?

The AM 3000 operates in complete autonomy thanks to its integrated lithium battery. The battery is encased in a protective aluminum housing, improving thermal stability and minimizing the risk of thermal runaway. In case of a power outage, the device will automatically switch to battery mode without interrupting the sampling.

How can users access the AM 3000’s sampling data?

Users can retrieve data in a computer file format (.CVS compatible with Excel) via a USB output. Additionally, using a USB/micro-USB cable and a text file reader or spreadsheet application like Excel, the file containing all the sampling details can be reviewed directly on a smartphone on site.

How does the AM 3000 ensure user convenience during operation?

The AM 3000 is fully programmable and can be remotely configured using an infrared remote control. A single remote control can operate all samplers, and the AM 3000 comes with two remote controls, including one backup.

What is the primary purpose of the AM 3000?

The AM 3000 is an autonomous air sampler specifically designed to meet the constraints and requirements of fieldwork. It ensures a representative sampling of asbestos fibers or other fine particles in the air, in accordance with NF X43-050, NF X43-269, and NF EN ISO 13137 standards.

 

 

Additional information

Admission

Self-sealing quick connector Ø int. 6 mm

Dimensions (L x H x P)

38 x 29 x 18 cm

Weight

sur secteur via chargeur 230V / 50 Hz

Volumetric Flow

from 2 to 9 L/min, regulated at the set point (mass flow meter with integrated temperature and pressure sensors). EMT: 2% guaranteed at 7L/min (4% for the rest of the range)

USB Output

text file type .CSV for data retrieval (up to 200 samples). USB/micro-USB cable available on request

Integrated Lithium-Ion Battery 24 V 21AH

Autonomy: Min. 30 hours at 7 l/min**
Charging Time: 8 hours

Maximum Power

17 W

Case

High-resistance copolymer. Waterproof rating IP 65 (cleanable under water jet)

User Interface

On backlit LCD screen with infrared remote control.

Programming (real-time clock)

16 programs

Regulation Failure

LED indicator

Recoverable Data

– Sampling number
– Start and end date/time of sampling
– Flow rate setting
– Duration setting
– Actual duration
– Start, end, and average temperature
– Start, end, and average atmospheric pressure
– Theoretical volume = set flow rate x duration
– Actual sampled volume
– Possible faults during sampling (regulation failure)
– End of sampling status
– Average flow rate: start & end

Maintenance menu secured by access code for

– Adjustment of regulation sensors (P, T°, Q)
– "Control due on …" indicator
– Setting of pressure drop threshold
– Customer reference
– Modification of maintenance access code