Recommended Items
-
AS 4000 et AS 4500 Aerosols & Iodine Sampler
- Iodine and aerosol trapping in compliance with the NF ISO 2889 standard
- Automatic air flow regulation from 20 to 100 Nl/min (from 30 to 100 Nl/min for AS4500)
- Mass flow meter: standardized airflow
- Reporting of fault alarms via T.O.R. relay contact (Ethernet optional)
- Visual indicator of start-up and pump activation
- Safety: lockable electrical cabinet
- Measurement of filter clogging level or potential leaks
- Ergonomic design with 2 handles for transportation
- Available in non-servo version: AS 4000 or servo version: AS 4500
-
MARC 7000 – Tritium Bubbler: Atmospheric Monitoring System with 4 Pots (With Oven) for Trapping Tritium in HTO, HT, and OBT Forms
- EFFICIENCY: The MARC 7000 monitors atmospheric tritium, capturing vapor and gas, with oxidation in an oven.
- PERFORMANCE: 99% HTO trapping efficiency and 98% oven conversion efficiency for precise tritium monitoring.
- INTEGRATED ADVANCED FUNCTIONS: Offers adjustable airflow, real-time display of various parameters, automatic regulation, and default data storage. Designed for user-friendly operation and accurate readings.
- PERFORMANCE: Automatic air flow regulation, durable diaphragm pump, and 316L stainless steel circuit.
- INTEGRATED ADVANCED FUNCTIONS: Adjustable air flow, automatic regulation, real-time display, and anomaly storage.
- OPTIONS FOR ENHANCED FUNCTIONALITY: Cooling circuit, Ethernet connectivity, and alarms.
- VERSATILE APPLICATIONS: Suitable for the nuclear industry, research centers, waste storage, and laboratories.
- SUPPLIER CONFIDENCE: Officially supplied to major organizations such as IRSN, the French Navy, EDF, ANDRA, CEA, and internationally to IAEA and various nuclear power plants.
- CERTIFICATION: NF ISO 20045 & NF ISO 20041-1
APPLICATIONS ·Nuclear Power Plants
·Industrial Use of Tritium
·Research on the Impact of Different Contamination Levels
·Radioactive Waste Storage and Treatment Sites
·Laboratories
·Incinerators
-
H3R 7000 : Tritium Condenser – Advanced Trapping of Atmospheric Tritium in Vapor Form
- INNOVATIVE DESIGN: The H3R 7000 is a revolutionary device for sampling tritium in the air, capable of capturing a representative sample of tritium in vapor form in ambient air in less than 40 minutes.
- HIGH PRECISION: The collected sample achieves a minimum detectable activity (MDA) of tritium in the air up to 0.01 Bq per cubic meter.
- EFFICIENT OPERATION: The H3R 7000 captures tritium in the form of water vapor through a process of cryogenizing the water vapor from the ambient air, ensuring accurate measurements.
- REAL-TIME MONITORING: Measures and records the absolute humidity of the ambient air in g/m3 in real-time.
- EXCEPTIONAL ADVANTAGES: 100% tritium trapping efficiency, suitable for indoor and outdoor use, allows multiple consecutive samplings in one day, guarantees 100% active samples, easy to use and transport, and offers data traceability.
- PATENTED TECHNOLOGY: Developed under a French patent filed internationally by the National Institute for Radioprotection and Nuclear Safety (I.R.S.N.) and the School of Military Applications of Atomic Energy (E.A.M.E.A./French Navy).
-
EDP 9002 – Double Mast Electrodeposition Equipment
- SPACE-SAVING & ECONOMICAL DESIGN: Two measurement stations on a single base, ideal for laboratories with limited workspace. The EDP 9002 is more affordable than purchasing two EDP 7000 devices.
- TIME EFFICIENCY: Significant time savings when conducting multiple analyses.
- SYNTHETIC MATERIALS: The EDP is made solely from synthetic materials that perfectly resist the sometimes highly corrosive environments of research laboratories, thus ensuring a very long lifespan for the device.
- HIGH PRECISION: Ensures optimal trapping efficiency with regulated and constant direct current. The EDP is equipped with a polarity reverser for electrochemical stripping of the stainless steel pellet intended to receive the deposit, thereby ensuring perfect purity of the support.
- COOLING SYSTEM: Features high-flow air convection, preventing solution evaporation thanks to a solution cooling system with high-flow air convection.
- VERSATILE SETTINGS: Adjust the current intensity up to 5 Amperes and the electrode rotation speed with precision potentiometers and three sizes for solution containers.
- DIGITAL TIMER: Set the exact duration of electrodeposition with a digital display timer and an audible alarm.
- EASY TO USE: Quick assembly/disassembly of bottles and an internal container for accidental spills. Easy user maintenance of the device. Almost instantaneous assembly/disassembly of bottles.
- COLLABORATION WITH COGEMA: Designed in association with the leading French nuclear institute.
-
MARC 5000 – Tritium Bubbler: Dual Pot Atmospheric Monitoring System (Without Oven) for Trapping Tritium in HTO Form
- EFFICIENCY: Precise monitoring of atmospheric Tritium (HTO only) with optimal trapping efficiency, suitable for long periods of activity thanks to its innovative cooling system (optional).
- VERSATILITY: Usable in various sectors, including nuclear power plants and nuclear medicine.
- AUTOMATIC REGULATION: Automatic adjustment of airflow based on pressure loss.
- PERFORMANCE: Regulated air flow, durable pump, and 316L stainless steel circuit.
- PRECISION: Particle filtration and real-time display of airflow/volume.
- SAFETY: Visual and remote alarms, with anomaly recording.
- RECOGNITION: Endorsed by renowned institutions such as IRSN, the French Navy, EDF, ANDRA, and CEA.
- CERTIFICATION: NF ISO 20045 & NF ISO 20041-1
APPLICATIONS ·Nuclear Power Plants
·Industrial Use of Tritium
·Research on the Impact of Different Contamination Levels
·Nuclear Medicine
-
HAGUE 7000 – Carbon 14 Bubbler with 4 Pots (with Oven)
- OPTIMAL MONITORING OF CARBON 14: The HAGUE 7000 effectively monitors atmospheric C14, capturing gas and organic compounds from various sources.
- ADVANCED OPERATING PRINCIPLE: Uses bubbling in a soda solution to trap gaseous C14 and similarly oxidizes organic C14.
- PRECISE MEASUREMENT: Accurately determines the volumetric activity of C14 in the air, with a 100% trapping efficiency for CO2 and 94% for CH4-CO2 conversion.
- COMPLIANCE WITH STANDARDS: Designed according to NF ISO 20041-1 standards for maximum efficiency and ergonomics.
- OPTIONAL COOLING FUNCTION: Cooling system available, maintaining the trapping solution at 7°C for consistent performance.
- CERTIFICATION: NF ISO 20041-1
APPLICATIONS · Nuclear Power Plants
· Nuclear Research Centers
· Radioactive Waste Storage and Treatment Sites
· Laboratories
· Incinerators
· Decommissioning or any industries incorporating Carbon 14
Best Seller Items
-
AS 4000 et AS 4500 Aerosols & Iodine Sampler
- Iodine and aerosol trapping in compliance with the NF ISO 2889 standard
- Automatic air flow regulation from 20 to 100 Nl/min (from 30 to 100 Nl/min for AS4500)
- Mass flow meter: standardized airflow
- Reporting of fault alarms via T.O.R. relay contact (Ethernet optional)
- Visual indicator of start-up and pump activation
- Safety: lockable electrical cabinet
- Measurement of filter clogging level or potential leaks
- Ergonomic design with 2 handles for transportation
- Available in non-servo version: AS 4000 or servo version: AS 4500
-
MARC 7000 – Tritium Bubbler: Atmospheric Monitoring System with 4 Pots (With Oven) for Trapping Tritium in HTO, HT, and OBT Forms
- EFFICIENCY: The MARC 7000 monitors atmospheric tritium, capturing vapor and gas, with oxidation in an oven.
- PERFORMANCE: 99% HTO trapping efficiency and 98% oven conversion efficiency for precise tritium monitoring.
- INTEGRATED ADVANCED FUNCTIONS: Offers adjustable airflow, real-time display of various parameters, automatic regulation, and default data storage. Designed for user-friendly operation and accurate readings.
- PERFORMANCE: Automatic air flow regulation, durable diaphragm pump, and 316L stainless steel circuit.
- INTEGRATED ADVANCED FUNCTIONS: Adjustable air flow, automatic regulation, real-time display, and anomaly storage.
- OPTIONS FOR ENHANCED FUNCTIONALITY: Cooling circuit, Ethernet connectivity, and alarms.
- VERSATILE APPLICATIONS: Suitable for the nuclear industry, research centers, waste storage, and laboratories.
- SUPPLIER CONFIDENCE: Officially supplied to major organizations such as IRSN, the French Navy, EDF, ANDRA, CEA, and internationally to IAEA and various nuclear power plants.
- CERTIFICATION: NF ISO 20045 & NF ISO 20041-1
APPLICATIONS ·Nuclear Power Plants
·Industrial Use of Tritium
·Research on the Impact of Different Contamination Levels
·Radioactive Waste Storage and Treatment Sites
·Laboratories
·Incinerators
-
H3R 7000 : Tritium Condenser – Advanced Trapping of Atmospheric Tritium in Vapor Form
- INNOVATIVE DESIGN: The H3R 7000 is a revolutionary device for sampling tritium in the air, capable of capturing a representative sample of tritium in vapor form in ambient air in less than 40 minutes.
- HIGH PRECISION: The collected sample achieves a minimum detectable activity (MDA) of tritium in the air up to 0.01 Bq per cubic meter.
- EFFICIENT OPERATION: The H3R 7000 captures tritium in the form of water vapor through a process of cryogenizing the water vapor from the ambient air, ensuring accurate measurements.
- REAL-TIME MONITORING: Measures and records the absolute humidity of the ambient air in g/m3 in real-time.
- EXCEPTIONAL ADVANTAGES: 100% tritium trapping efficiency, suitable for indoor and outdoor use, allows multiple consecutive samplings in one day, guarantees 100% active samples, easy to use and transport, and offers data traceability.
- PATENTED TECHNOLOGY: Developed under a French patent filed internationally by the National Institute for Radioprotection and Nuclear Safety (I.R.S.N.) and the School of Military Applications of Atomic Energy (E.A.M.E.A./French Navy).
-
EDP 9002 – Double Mast Electrodeposition Equipment
- SPACE-SAVING & ECONOMICAL DESIGN: Two measurement stations on a single base, ideal for laboratories with limited workspace. The EDP 9002 is more affordable than purchasing two EDP 7000 devices.
- TIME EFFICIENCY: Significant time savings when conducting multiple analyses.
- SYNTHETIC MATERIALS: The EDP is made solely from synthetic materials that perfectly resist the sometimes highly corrosive environments of research laboratories, thus ensuring a very long lifespan for the device.
- HIGH PRECISION: Ensures optimal trapping efficiency with regulated and constant direct current. The EDP is equipped with a polarity reverser for electrochemical stripping of the stainless steel pellet intended to receive the deposit, thereby ensuring perfect purity of the support.
- COOLING SYSTEM: Features high-flow air convection, preventing solution evaporation thanks to a solution cooling system with high-flow air convection.
- VERSATILE SETTINGS: Adjust the current intensity up to 5 Amperes and the electrode rotation speed with precision potentiometers and three sizes for solution containers.
- DIGITAL TIMER: Set the exact duration of electrodeposition with a digital display timer and an audible alarm.
- EASY TO USE: Quick assembly/disassembly of bottles and an internal container for accidental spills. Easy user maintenance of the device. Almost instantaneous assembly/disassembly of bottles.
- COLLABORATION WITH COGEMA: Designed in association with the leading French nuclear institute.
-
MARC 5000 – Tritium Bubbler: Dual Pot Atmospheric Monitoring System (Without Oven) for Trapping Tritium in HTO Form
- EFFICIENCY: Precise monitoring of atmospheric Tritium (HTO only) with optimal trapping efficiency, suitable for long periods of activity thanks to its innovative cooling system (optional).
- VERSATILITY: Usable in various sectors, including nuclear power plants and nuclear medicine.
- AUTOMATIC REGULATION: Automatic adjustment of airflow based on pressure loss.
- PERFORMANCE: Regulated air flow, durable pump, and 316L stainless steel circuit.
- PRECISION: Particle filtration and real-time display of airflow/volume.
- SAFETY: Visual and remote alarms, with anomaly recording.
- RECOGNITION: Endorsed by renowned institutions such as IRSN, the French Navy, EDF, ANDRA, and CEA.
- CERTIFICATION: NF ISO 20045 & NF ISO 20041-1
APPLICATIONS ·Nuclear Power Plants
·Industrial Use of Tritium
·Research on the Impact of Different Contamination Levels
·Nuclear Medicine
-
HAGUE 7000 – Carbon 14 Bubbler with 4 Pots (with Oven)
- OPTIMAL MONITORING OF CARBON 14: The HAGUE 7000 effectively monitors atmospheric C14, capturing gas and organic compounds from various sources.
- ADVANCED OPERATING PRINCIPLE: Uses bubbling in a soda solution to trap gaseous C14 and similarly oxidizes organic C14.
- PRECISE MEASUREMENT: Accurately determines the volumetric activity of C14 in the air, with a 100% trapping efficiency for CO2 and 94% for CH4-CO2 conversion.
- COMPLIANCE WITH STANDARDS: Designed according to NF ISO 20041-1 standards for maximum efficiency and ergonomics.
- OPTIONAL COOLING FUNCTION: Cooling system available, maintaining the trapping solution at 7°C for consistent performance.
- CERTIFICATION: NF ISO 20041-1
APPLICATIONS · Nuclear Power Plants
· Nuclear Research Centers
· Radioactive Waste Storage and Treatment Sites
· Laboratories
· Incinerators
· Decommissioning or any industries incorporating Carbon 14
-
Constant Level Infiltrometer – With or Without 15cm Auger – For Soil Permeability Tests for Autonomous Sanitation
- SOIL PERMEABILITY MEASUREMENT: The SDEC Constant Level Infiltrometer is designed to measure the soil’s saturated hydraulic conductivity (K coefficient), a key data point in determining soil’s ability to infiltrate water, essential for permeability tests in autonomous sanitation.
- RELIABLE PORCHET METHOD: Uses the constant level Porchet method to conduct precise percolation tests, measuring the rate of water absorption by the soil from shallow water-filled holes.
- CREATION OF A SATURATED BULB: Before measurement, a sufficient volume of water is percolated to create a saturated bulb in the soil around the hole, allowing for an accurate assessment of the soil’s infiltration capacity.
- COMPLETE KIT: Includes a stainless steel level control cell, HDPE saturation and measuring tanks, digital stopwatch, transport case, Edelman auger, and connectors, providing everything needed for reliable and practical measurements.
- PRACTICALITY AND PRECISION: The SDEC Constant Level Infiltrometer combines ease of installation and precision in measurements, proving to be an indispensable tool for professionals in autonomous sanitation and soil studies.
NOTE: There are two options for the kit, with or without the auger, to be specified at the time of purchase.
-
Variable Charge Double Ring Infiltrometer of the Müntz Type – Easy to Implement
- EASY MEASUREMENT OF SURFACE WATER INFILTRATION: The Müntz method of this infiltrometer allows easy measurement of the rate of water infiltration at the soil surface, making this device ideal for various applications.
- COMPACT AND ROBUST DESIGN: The infiltrometer, consisting of a single piece, is easy to transport and install, thanks to its sturdy and compact construction.
- ACCURATE MEASUREMENTS WITH TRIPLE RINGS: Equipped with triple rings, the infiltrometer offers representative average measurements of the superficial soil horizons, particularly useful for gravity irrigation recommendations.
- COMPLETE KIT FOR OPTIMAL USE: The set includes a double-ring infiltrometer with essential accessories such as a graduated float, a guide for the float, a rebound-free hammer, and a stopwatch.
- VERSATILE APPLICATIONS: The infiltrometer is crucial for assessing infiltration capacity in various contexts such as irrigation installations, soil permeability study, and the usability of sports fields.
-
Constant Charge Double Ring Infiltrometer of the Müntz Type – Easy to Implement
- MESURE EFFICACE DE L’INFILTRATION D’EAU : Le SDEC Infiltromètre à double anneau de type Müntz à charge constante facilite la mesure de la vitesse d’infiltration de l’eau en surface, idéal pour des contextes variés, notamment les projets d’irrigation et d’étude du sol.
- CONCEPTION PRATIQUE ET TRANSPORTABLE : Constitué d’une seule pièce, l’appareil est facile à transporter et installer, avec des triples anneaux pour une moyenne représentative des mesures d’infiltration, surtout dans les couches superficielles du sol.
- SET COMPLET POUR UNE UTILISATION OPTIMALE : Inclut un infiltromètre à double anneau avec des diamètres intérieurs adaptés, un flotteur avec tige graduée, un guide, un marteau anti-rebond et un chronomètre, fournissant tout le nécessaire pour une mesure précise.
- APPLICATIONS POLYVALENTES : L’infiltromètre est crucial pour évaluer la capacité d’infiltration du sol dans des contextes tels que l’irrigation, l’étude de la perméabilité, et la praticabilité des terrains de sport.
- PRÉCISION ACCRUE GRÂCE AUX TRIPLES ANNEAUX : Offre une grande précision des résultats, grâce à sa conception à charge constante et ses triples anneaux, parfaits pour les recommandations d’irrigation gravitaire.
-
Storage Case for SDEC Infiltrometer
- OPTIMIZED STORAGE FOR INFILTROMETER: The SDEC storage case is specially designed for the SDEC Infiltrometer, offering a secure and organized storage solution, essential for transporting and protecting this precise equipment.
- DURABLE AND PROTECTIVE DESIGN: Made with robust materials, the case ensures durability and optimal protection against shocks, dust, and other potential damages, thereby extending the lifespan of the Infiltrometer.
- EASE OF TRANSPORT: Featuring an ergonomic handle and an adapted interior layout, this case allows for easy and convenient transport of the SDEC Infiltrometer, making travel to study sites and construction sites more convenient and efficient.
-
Stopwatch for SDEC Infiltration Set
- EASE OF USE AND RELIABILITY: Equipped with a simple and intuitive interface, this stopwatch ensures easy and reliable use in the field. Its robust design guarantees consistent performance in various environmental conditions.
-
Battery Operated Field Electric Vacuum Pump PAV 2000 : For soil sampling
- RAPID VACUUM CREATION: Achieves a vacuum of -750 mbar in less than 15 seconds, significantly speeding up soil sampling.
- HIGH AUTONOMY & PORTABILITY: Offers 5 hours of continuous operation with a lightweight and durable aluminum design for convenience in the field.
- INTEGRATED SMART CHARGING SYSTEM: Includes a maintenance-free 12V, 5A/hour battery with a smart charger for easy recharging.
- PRECISION & PROTECTION: Equipped with an accurate Bourdon-type manometer and a Gore-Tex filter to guard against water ingress.
- COMPACT & EASY TO USE: Compact dimensions (200mm x 130mm x 240mm) with a simple three-position operational switch.
APPLICATIONS · Vacuum creation in soil solution extraction rods (ref. SPS 200)
· Vacuum creation for effective water degassing in TENSOMETRY (ref. SMS 2000, SR 1000, STM 2150, etc.).
· Any applications where rapid vacuum creation is sought